Skip to main navigation Skip to search Skip to main content

Tumor-preserving Deformable Registration of Longitudinal DCE Breast MRI during Neoadjuvant Chemotherapy

  • Luyi Han
  • , Tao Tan
  • , Tianyu Zhang
  • , Yuan Gao
  • , Xin Wang
  • , Valentina Longo
  • , Sofía Ventura-Díaz
  • , Anna D’angelo
  • , Yue Sun
  • , Jonas Teuwen
  • , Ritse Mann
  • Radboud University Nijmegen
  • Netherlands Cancer Institute
  • Catholic University of the Sacred Heart
  • Hospital Ramon y Cajal
  • IRCCS Roma
  • Macao Polytechnic University

Research output: Contribution to journal › Article › peer-review

2 Citations (Scopus)

Abstract

Purpose: To develop a deep learning–based deformable registration method for dynamic contrast-enhanced (DCE) breast MRI that preserves tumor regions while maintaining global anatomic alignment during neoadjuvant chemotherapy (NAC) response assessment. Materials and Methods: This retrospective study included internal and external cohorts of patients with breast cancer who were undergoing NAC. The internal cohort comprised patients who underwent DCE MRI from 2017 to 2020, and the external cohort was derived from the I-SPY2 trial. A conditional pyramid registration network integrating unsupervised keypoint detection with a volume-preserving mechanism was developed. Registration performance was evaluated using the Dice similarity coefficient (DSC), average landmark error, and tumor volume difference. A local-global biomarker derived from registered images was evaluated for predicting pathologic complete response (pCR) using the area under the receiver operating characteristic curve (AUC) and accuracy. Paired t tests were used for statistical comparisons. Results: In 314 patients (all female; age, 50.6 years ± 12.0 [SD]) with 1630 scans in the internal cohort, the proposed method achieved a DSC of 0.95 ± 0.02, an average landmark error of 5.35 mm ± 3.46, and a tumor volume difference of 11.0% ± 10.7. In 100 patients (all female; age, 48.5 years ± 12.3) with 372 scans in the external cohort, the method achieved a DSC of 0.91 ± 0.09 and a tumor volume difference of 15.5% ± 13.8. Improvements in landmark distance and tumor preservation were statistically significant (P < .05) compared with most methods. For pCR prediction, incorporation of the proposed biomarker achieved an AUC of 0.81 ± 0.04 and an accuracy of 72.1% ± 5.0. Conclusion: The proposed framework improved anatomic alignment while preserving tumor volume in longitudinal DCE breast MRI during NAC response assessment and enabled a registration-based biomarker for predicting treatment response.

Original languageEnglish
Article numbere250789
JournalRadiology: Artificial Intelligence
Volume8
Issue number4
DOIs
Publication statusPublished - Jul 2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Breast
  • DCE Breast MRI
  • Deep Learning
  • Deformable Registration
  • Image Postprocessing
  • MR Imaging
  • Neoadjuvant Chemotherapy
  • Neural Networks
  • Prognosis
  • Radiomics
  • Unsupervised Keypoint Detection

Fingerprint

Dive into the research topics of 'Tumor-preserving Deformable Registration of Longitudinal DCE Breast MRI during Neoadjuvant Chemotherapy'. Together they form a unique fingerprint.

Cite this