跳至主導覽 跳至搜尋 跳過主要內容

A Transducer-Adaptive Denoising Model for Medical Ultrasound Imaging

  • Mingfu Jiang
  • , Chenzhi You
  • , Xiang Li
  • , Xiangyu Xiong
  • , Jun Li
  • , Mingwei Wang
  • , Yuqi Guo
  • , Yao Xiao
  • , Yuyu Bai
  • , Dawei Wu
  • , Tao Tan
  • Macao Polytechnic University
  • Xinyang Agriculture and Forestry University
  • Nanjing University of Aeronautics and Astronautics
  • Acoustic Life Science Co., Ltd.
  • Kiang Wu Hospital
  • Affiliated Hospital of Hangzhou Normal University
  • Air Force Medical University

研究成果: Article同行評審

摘要

Ultrasound imaging is a pivotal diagnostic tool in medical practice due to its noninvasive nature, low cost, and real-time imaging capabilities. However, the images are often affected by various types of noise, significantly degrading image quality and hindering accurate diagnosis. Traditional filtering methods struggle to preserve fine image details, while machine learning and deep learning-based models often lack adaptability to different ultrasound instruments and transducer configurations. To address these challenges, we propose a novel deep learning-based ultrasound image denoising model. Our model uses a multibranch convolutional neural network (CNN) structure to configure metadata based on sensor configuration center frequency, element kerf, element width, and imaging depth adaptively adjusts the noise level and denoising intensity, effectively suppressing speckle noise and preserving texture details in images from different ultrasound instruments. It is trained and evaluated primarily on ultrasound images synthesized using coherent plane wave compounding (CPWC), chosen for its standardized and reproducible framework. Despite being trained on CPWC data, our model demonstrates competitive denoising performance for non-CPWC-based ultrasound images, attributing to the shared physical factors influencing speckle generation. The results demonstrate that our model outperforms existing denoising methods, with average SSIM, PSNR, and EI values increased by 1.67%, 1.28%, and 1.04%, respectively. Additionally, when applied to real breast ultrasound images, our denoising method achieves state-of-the-art results in downstream image classification tasks, significantly improving both accuracy and AUC values. This study holds practical significance in enhancing the quality of ultrasound images for improved clinical diagnosis.

原文English
頁(從 - 到)3759-3771
頁數13
期刊IEEE Transactions on Artificial Intelligence
7
發行號7
DOIs
出版狀態Published - 1 7月 2026

指紋

深入研究「A Transducer-Adaptive Denoising Model for Medical Ultrasound Imaging」主題。共同形成了獨特的指紋。

引用此