Application of the Error Function Model in the Constant Pressure Backwash Membrane Process

研究成果: Conference contribution同行評審

摘要

A error function model was established to predict the total resistance of a 0.1 μm polyacrylonitrile (PAN) flat-sheet microfiltration membranes fouled with 1.46 g/L activated sludge suspension during the constant pressure backwash process under different operating conditions (backwash strength and temperature). The results showed that the total resistance of the fouled membrane decreased with increasing backwash intensity or temperature. The model predictions aligned well with experimental data under all tested conditions (R2 > 0.91). Additionally, the model parameter k effectively evaluated cleaning efficacy: smaller k value indicating better cleaning efficiency.

原文English
主出版物標題Conference Proceedings of the 13th International Symposium on Project Management, ISPM 2025
編輯Cheng Changbo, Henry Zhang
發行者Aussino Academic Publishing House
頁面1045-1049
頁數5
ISBN(電子)9798331324933
DOIs
出版狀態Published - 2025
事件13th International Symposium on Project Management, ISPM 2025 - Beijing, China
持續時間: 27 6月 202528 6月 2025

出版系列

名字Conference Proceedings of the 13th International Symposium on Project Management, ISPM 2025
2

Conference

Conference13th International Symposium on Project Management, ISPM 2025
國家/地區China
城市Beijing
期間27/06/2528/06/25

指紋

深入研究「Application of the Error Function Model in the Constant Pressure Backwash Membrane Process」主題。共同形成了獨特的指紋。

引用此