TY - JOUR
T1 - Assessment of air quality and performance of central ventilation system
AU - Chan, K. H.
PY - 2011/7
Y1 - 2011/7
N2 - Central HVAC is a critical constructed facility in the built environment, yet polluted air quality has been causing environment, health, and safety problems to end-users worldwide, particularly in multistory commercial buildings with such systems installed. An index system was introduced in Hong Kong to measure the external air quality, but no system has yet been introduced for measuring internal air quality, nor the legislation to control it. The Hong Kong government states that more than 32% of commercial buildings and 37% of shopping arcades have sick building syndrome, which leads to nausea, dizziness, headaches, sore throats, nose irritation, sinus congestion, and other symptoms in the occupiers. In this study, the major causes, design, construction, users' habitual modes, and mitigating measures will be investigated, with supporting case studies in Hong Kong. A preliminary investigation, air sample analysis, and end-users' feedback from questionnaires will be gathered and analyzed to establish a long-term solution for air quality problems.
AB - Central HVAC is a critical constructed facility in the built environment, yet polluted air quality has been causing environment, health, and safety problems to end-users worldwide, particularly in multistory commercial buildings with such systems installed. An index system was introduced in Hong Kong to measure the external air quality, but no system has yet been introduced for measuring internal air quality, nor the legislation to control it. The Hong Kong government states that more than 32% of commercial buildings and 37% of shopping arcades have sick building syndrome, which leads to nausea, dizziness, headaches, sore throats, nose irritation, sinus congestion, and other symptoms in the occupiers. In this study, the major causes, design, construction, users' habitual modes, and mitigating measures will be investigated, with supporting case studies in Hong Kong. A preliminary investigation, air sample analysis, and end-users' feedback from questionnaires will be gathered and analyzed to establish a long-term solution for air quality problems.
KW - Air quality management
KW - Air source control
KW - Central HVAC system
KW - Sick building
KW - Ventilation improvement
UR - https://www.scopus.com/pages/publications/80051641123
U2 - 10.1061/(ASCE)CF.1943-5509.0000168
DO - 10.1061/(ASCE)CF.1943-5509.0000168
M3 - Article
AN - SCOPUS:80051641123
SN - 0887-3828
VL - 25
SP - 326
EP - 335
JO - Journal of Performance of Constructed Facilities
JF - Journal of Performance of Constructed Facilities
IS - 4
ER -